English (en) | Change Language

Sort: Relevance | Newest first | Oldest first


1 items found (Showing 1 - 1)
  1. This study investigated the main factors influencing digester temperature and methods to reduce heat losses during the cold season in the subtropics. Four composite digesters (two insulated and two uninsulated) were buried underground to measure their internal temperature (C) at a depth of 140 cm...  

Looking for more results?

Ask the community about *